6. The EG8 is designed to be operated by a 24VAC power source
Installation
1. Remove the dome.
2. Disconnect the PTZ camera from its base by pushing in and twisting
counter clockwise. Set aside.
3. Apply thread sealant (included) to the 1½” NPT pipe threads or
approved mount. This procedure will prevent moisture ingress through
the threads. [Figure 2]
the threads. [Figure 2]
WARNING
Failure to properly seal the 1½” NPT pipe
threads will permit water to enter the housing
and may damage the internal equipment.
and may damage the internal equipment.
4. Install EG8 assembly on 1½” NPT pipe or mount by rotating counter-
clockwise until threads are fully engaged.
5. Detach the camera mounting plate from the housing and allow it to be
suspended by tether.
6. Remove foam dust cap and route CAT5 and power cables into the housing.
7. Connect 24VAC to the input terminals on circuit board marked “+IN-.”
[Figure 3]
8. Insert end of CAT5 into the RJ45 jack in the IP encoder module. [Figure
4]
9. Push extra wire length up through housing flange and re-install the foam
dust cap in the cable entrance of the housing.
10. Reinstall and tighten the screws holding the camera mounting plate.
11. Reconnect the PTZ camera to its base on the camera mounting plate by
pressing onto the plate and turning clockwise.
12. Reinstall dome assembly and tighten screws to ensure a proper seal with
the dome gasket.
Electrical Properties
•
Input Voltage = 24VAC ± 10%
•
Power = 2.5A @ 24VAC (w/ heater on)
•
Blower = 4.7 CFM (2.2 watts) (continuous operation)
•
Heater = 40 watts
Optional Mounts
(consult factory for color and style options)
•
Curved Wall Mount
HM11xx
•
Pole Mount
HM12xx (requires HM11xx)
•
Corner Mount
HM13xx (requires HM11xx)
•
Roof (Parapet) Mount
HM14xx (requires HM11xx)
FIGURE 3
FIGURE 4
FIGURE 1
FIGURE 2