Hisense kf-2302gwe 사용자 가이드
9
(3) Install the indoor unit on the rear panel.
(4) Connect the tubing and wiring led inside from
(4) Connect the tubing and wiring led inside from
outdoors.
(5)After completing a leak test, bundle the tubing
together with armoring tape and store it inside
the tubing storage area at the back of the
indoor unit and hold it with clamps.
the tubing storage area at the back of the
indoor unit and hold it with clamps.
To unmouht indoor unit
Press the 2 marks on the lower part of the indoor
unit and unlatch the tabs. Then lift the indoor
unit and unmount. (Fig.25)
unit and unlatch the tabs. Then lift the indoor
unit and unmount. (Fig.25)
3-9. Drain Hose
a) The drain hose should be slanted downward to the
a) The drain hose should be slanted downward to the
outdoors.(Fig.26)
b) Never form a trap in the course of the hose.
c) If the drain hose will run in the room, insulate
c) If the drain hose will run in the room, insulate
the hose with insulation * so that chilled
condensation will not damage furniture of floors.
(Fig.27)
condensation will not damage furniture of floors.
(Fig.27)
*Foamed
polyethylene
of
its
equivalent
is
recommended.
WARNING
Do not supply power to
the unit or operate it
until all tubing and
wiring to the outside
unit are completed.
the unit or operate it
until all tubing and
wiring to the outside
unit are completed.
Risk of Electric Shock
4.HOW TO INSTALL THE OUTSIDE UNIT
First refer to Section 2. Installation Site Selection.
NOTE
The drain hole at the bottom of the outdoor unit
was not plugged at the time of factory shipment.
If necessary, mount the accessory drain elbow
If necessary, mount the accessory drain elbow
before installing the outdoor unit. (Fig.28)
4-1.Wiring Instruction for Outdoor Unit
Regulations on wire size differ from locality to
locality. For field wiring requirements, please
locality. For field wiring requirements, please
refer to your local electrical codes. Make sure
that the installation fully complies with all
that the installation fully complies with all
local and national regulations.
(1)Remove access panel“C”.(Fig.29)
(2)Connect the inter-unit wiring and power line
according to the drawing inside panel “C”.
(3)Be sure to size each wire allowing approx. 10cm
longer than the required length for wiring.
Store wire strands inside the cabinet.
Store wire strands inside the cabinet.
(4)When connection are completed, check that all
connections are correct as shown in the wiring
system diagram inside access panel“C”.
system diagram inside access panel“C”.
(5)Be sure to ground the unit according to your
local codes.
5.REFRIGERANT TUBING
5-1.Use of the Flaring Method
5-1.Use of the Flaring Method
Push
Fig.25
Drain hose
Clamp
Drain cap
To slip on
To remove
o
60
Fig.23c
Fig.24
Refrigerant tubing
Inter-unit wiring
Drain hose
Fig.26
Fig.27
Slant
Indoor
unit
unit
Drain
hose
hose
Condensation
Insulation material
(locally purchased)
must be used.
(locally purchased)
must be used.
Outdoor
unit
unit
Accessory
drain elbow
drain elbow
Fig.28