9
(3)  Install the indoor unit on the rear panel.
(4)  Connect  the  tubing  and  wiring  led  inside  from 
outdoors.
(5)After completing a leak test, bundle the tubing 
together with armoring tape and store it inside 
the  tubing  storage  area  at  the  back  of  the 
indoor unit and hold it with clamps.
To unmouht indoor unit
Press the 2   marks on the lower part of the indoor 
unit  and  unlatch  the  tabs.  Then  lift  the  indoor 
unit and unmount. (Fig.25)
3-9. Drain Hose 
a) The drain hose should be slanted downward to the 
outdoors.(Fig.26)
b) Never form a trap in the course of the hose.
c) If the drain hose will run in the room, insulate 
the  hose  with  insulation  *  so  that  chilled 
condensation will not damage furniture of floors. 
(Fig.27)
*Foamed 
polyethylene 
of 
its 
equivalent 
is 
recommended.   
WARNING
Do not supply power to
the unit or operate it 
until  all  tubing  and 
wiring  to  the  outside 
unit are completed.
Risk of Electric Shock
4.HOW TO INSTALL THE OUTSIDE UNIT
First refer to Section 2. Installation Site Selection.
NOTE
The  drain  hole  at  the  bottom  of  the  outdoor  unit 
was  not  plugged  at  the  time  of  factory  shipment. 
If  necessary,  mount  the  accessory  drain  elbow 
before installing the outdoor unit. (Fig.28)
4-1.Wiring Instruction for Outdoor Unit
Regulations  on  wire  size  differ  from  locality  to 
locality.  For  field  wiring  requirements,  please 
refer  to  your  local  electrical  codes.  Make  sure 
that  the  installation  fully  complies  with  all 
local and national regulations.
(1)Remove access panel“C”.(Fig.29)
(2)Connect  the  inter-unit  wiring  and  power  line 
according to the drawing inside panel “C”.
(3)Be sure to size each wire allowing approx. 10cm 
longer  than  the  required  length  for  wiring. 
Store wire strands  inside the cabinet.
(4)When  connection  are  completed,  check  that  all 
connections  are  correct  as  shown  in  the  wiring 
system diagram inside access panel“C”.
(5)Be  sure  to  ground  the  unit  according  to  your 
local codes.
5.REFRIGERANT TUBING 
5-1.Use of the Flaring Method
Push
Fig.25
Drain hose
Clamp
Drain cap
To slip on
To remove
o
60
Fig.23c
Fig.24
Refrigerant tubing
Inter-unit wiring
Drain hose
Fig.26
Fig.27
Slant
Indoor
unit
Drain
hose
Condensation
Insulation material
(locally purchased)
must be used.
Outdoor
unit
Accessory
drain elbow
Fig.28