3com S7906E 참조 가이드
1-22
Field
Description
Metric Cost
value
Next-Hop Next
hop
Interface Outbound
interface
display ospfv3 vlink
Syntax
display ospfv3 [ process-id ] vlink
View
Any view
Default Level
1: Monitor level
Parameters
process-id: Specifies the ID of an OSPFv3 process, ranging from 1 to 65535.
Description
Use the display ospfv3 vlink command to display OSPFv3 virtual link information. If no process is
specified, virtual link information of all OSPFv3 processes is displayed.
Examples
# Display OSPFv3 virtual link information.
<Sysname> display ospfv3 vlink
Virtual Link VLINK1 to router 1.1.1.1 is up
Transit area :0.0.0.1 via interface Vlan-interface100, instance ID: 0
Local address: 2000:1::1
Remote address: 2001:1:1::1
Transmit Delay is 1 sec, State: P-To-P,
Timer intervals configured, Hello: 10, Dead: 40, Wait: 40, Retransmit: 5
Hello due in 00:00:02
Adjacency state :Full
Table 1-18 display ospfv3 vlink command output description
Field
Description
Virtual Link VLINK1 to router 1.1.1.1 is up
The virtual link VLINK1 to router 1.1.1.1 is up
Transit area 0.0.0.1 via interface
Vlan-interface100
Vlan-interface100
Interface Vlan-interface100 in transit area
0.0.0.1.
0.0.0.1.
instance ID
Instance ID
Local address
Local IPv6 address
Remote address
Remote IPv6 address