Package Contents
Switch 4900 SX (3C17702)
CD-ROM
Management Quick Reference Guide
Getting Started Guide (this guide)
Implementation Guide
Release Notes
Registration Information
Power Cord 
2 x mounting brackets
6 x screws
4 x rubber feet
Choosing a Suitable 
Site
The Switch is suited for use in a network room, or telecommunications 
room, where it can be mounted in a standard 19-inch equipment rack, or 
free-standing. Alternatively, the Switch can be rack-mounted in a wiring 
closet or equipment room. A rack-mounting kit, containing two 
mounting brackets and six screws is supplied with the unit.
CAUTION: Ensure that the ventilation holes are not obstructed.
When deciding where to position the Switch, ensure that:
Cabling is located away from:
sources of electrical noise such as radios, transmitters and 
broadband amplifiers. 
power lines and fluorescent lighting fixtures
The Switch is accessible and cables can be connected easily.
Water or moisture cannot enter the case of the Switch.
Air-flow is not restricted around the Switch or through the vents in the 
side of the Switch. 3Com recommends that you provide a minimum of 
25 mm (1 in.) clearance.
Air flow around the Switch does not exceed 40 
°C
 (104 
°
F).
If the Switch is installed in a 19-inch rack or closed assembly its local air 
temperature may be greater than room ambient temperature.
The air is as free from dust as possible.