Rack-mounting
19
The unit is installed in a clean, air conditioned environment.
No more than four Switch units are placed on top of one another, if 
the units are free-standing. 
Ensure there is adequate clearance at the front of the unit to ensure 
that the fibers are not damaged as they have a restricted bend radius.
Rack-mounting
The Switch 4900 SX is 1.5U and will fit in most standard 19-inch racks. 
However, as each Switch requires a shelf or runner to support its weight, 
you will need to allow a 2U space within the rack for each Switch.
WARNING: The switch should only be used in a rack if it is mounted on 
runners, a shelf, or a tray to support the weight. The rack-mount kits 
alone are not sufficient to support the weight of the switch. The rack 
mount kits must not be used to suspend the Switch from under a table or 
desk, or attach it to a wall.
CAUTION: You must use a full depth shelf or support that will not 
obstruct the air flow through the side panels of the Switch 4900 SX.
CAUTION: Disconnect all cables from the Switch before continuing. 
Remove all self adhesive pads from the underside of the Switch if they 
have been fitted.
To rack-mount your Switch:
Place the Switch the right way up on a hard flat surface, with the front 
facing towards you.
Locate a mounting bracket over the mounting holes on one side of the 
Switch, as shown in 
Figure 3   Fitting a bracket for rack-mounting