Example
# Set the link state polling interval to 20 seconds for interface serial 1/0.
<Sysname> system-view
[Sysname] interface serial 1/0
[Sysname-Serial1/0] timer hold 20 
virtualbaudrate
Syntax
virtualbaudrate virtualbaudrate
undo virtualbaudrate
View
Synchronous serial interface view
Parameter
virtualbaudrate: Baud rate (in bps) to be set, which must be consistent with the 
one configured at the DCE side. It can be 1,200, 2,400, 4,800, 9,600, 19,200, 
38,400, 56,000, 57,600, 64,000, 72,000, 115,200, 128,000, 192,000, 256,000, 
384,000, 512,000, 768,000, 2,048,000, or 4,096,000.
Description
Use the virtualbaudrate command to set a virtual baud rate for the DTE 
interface.
Use the undo virtualbaudrate command to remove the specified virtual baud 
rate.
When working as DTE, the serial interface determines its baud rate through 
negotiation with the DCE side. The virtualbaudrate command, however, allows 
you to configure DTE-side baudrate manually, but the configured value must be 
the same as the one set at the DCE side.
After executing the virtualbaudrate command, you need to shut down and then 
bring up the interface (using the shutdown command and the undo shutdown 
command) for the new setting to take effect.
n
Configure the baudrate command at DCE side and the virtualbaudrate 
command at DTE side (only when the interface is operating in synchronous 
mode). Avoid configuring the two commands at the same end of a link.
At DCE side, the display interface command displays the baud rate of the 
interface; whereas at the DTE end, the command displays the virtual baud rate 
of the interface.
Related command:
Example
# Set the virtual baudrate of DTE interface Serial 1/0 to 19,200 bps.
<Sysname> system-view
[Sysname] interface serial 1/0
[Sysname-Serial1/0] virtualbaudrate 19200