3com MSR 20-20 참조 매뉴얼

다운로드
페이지 2742
2272
C
HAPTER
 149: NQA C
LIENT
 C
ONFIGURATION
 C
OMMANDS
Parameter
interval: Interval between two consecutive tests, in milliseconds, in the range 0 to 
604800000. If the interval is 0, it indicates that only one test is performed.
Description
Use the frequency command to configure the interval between two consecutive 
tests for a test group.
Use the undo frequency command to restore the default.
By default, the interval between two consecutive tests for a test group is 0 
milliseconds, that is, only one test is performed.
After you use the nqa schedule command to start an NQA test, one test is started 
at interval.
n
If the last test is not completed when the interval specified by the frequency 
command is reached, a new test is not started.
Example
# Configure the interval between two consecutive tests as 1000 milliseconds.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] frequency 1000 
history-records
Syntax
history-records number
undo history-records
View
Any NQA test type view
Parameter
number: Maximum number of history records that can be saved in a test group, in 
the range 0 to 50.
Description
Use the history-records command to configure the maximum number of history 
records that can be saved in a test group.
Use the undo history-records command to restore the default.
By default, the maximum number of records that can be saved in a test group is 
50.
If the number of history records exceeds the maximum number, the earliest history 
record for a probe will be discarded.
Example
# Configure the maximum number of history records that can be saved in a test 
group as 10.
<Sysname> system-view
[Sysname] nqa entry admin test