305
oam frequency
Syntax
oam frequency frequency [ up up-count down down-count retry-frequency 
retry-frequency ]
undo oam frequency
View
PVC view/ATM Class view
Parameter
frequency: Time interval to send operations, administration, and maintenance 
(OAM) F5 Loopback cells, in seconds, and the range of the value is 1 to 600.
up-count: Number of OAM F5 Loopback cells. A PVC goes up only when the 
number of the OAM F5 Loopback cells successively and correctly received reaches 
the number specified by this argument. This argument ranges from 1 to 600. The 
system default is 3.
down-count: Number of OAM F5 Loopback cells. A PVC goes down only when 
the number of the successive OAM F5 Loopback cells not received reaches the 
number specified by this argument. This argument ranges from 1 to 600. The 
system default is 5.
retry-frequency: Interval (in seconds) to send OAM F5 Loopback cell in 
retransmission detection before PVC status changes. This argument ranges from 1 
to 1,000. The system default is 1.
Description
Use the oam frequency command to enable the transmission and 
retransmission detection of OAM F5 Loopback cell, as well as to modify the related 
parameters.
Use the undo oam frequency command to disable the transmission and 
retransmission detection of the cell.
By default, OAM F5 Loopback cell transmission is disabled, but if an OAM F5 
Loopback cell is received, it should be responded.
The oam frequency command is not applicable to the secondary PVCs of a PVC 
group.
Example
# Enable OAM F5 Loopback detection on PVC 1/32, with the period of 12 
seconds. And set the retransmission detection up-count as 4, down-count as 4 
and retransmission period as 1 second.
<Sysname> system-view
[Sysname] interface atm 1/0
[Sysname-Atm1/0] pvc 1/32
[Sysname-atm-pvc-Atm1/0-1/32] oam frequency 12 up 4 down 4 retry-frequency 1