3com MSR 20-20 참조 매뉴얼

다운로드
페이지 2742
306
C
HAPTER
 19: ATM C
ONFIGURATION
 C
OMMANDS
oamping interface
Syntax
oamping interface atm interface-number pvc { pvc-name | vpi/vci } [ number 
timeout 
]
View
ATM interface view
Parameter
atm interface-number: ATM interface number.
pvc-name: PVC name, a unique string of 1 to 16 characters on ATM interface, not 
case-sensitive. The name cannot be the same as a valid VPI/VCI pair value. For 
example, the name 1/20 is not allowed.
vpi/vci: VPI/VCI pair. VPI is short for virtual path identifier; its value ranges from 0 
to 255. VCI is short for virtual channel identifier; its value range varies by interface 
type. Normally, VCI values from 0 to 31 are reserved for special purpose, you are 
not recommended to use them. For details regarding the value range, refer to 
Table 28.
number: Number of OAM cells to be transmitted consecutively, in the range 1 to 
1,000. The system default is 5.
timeout: OAM response timeout period in seconds, in the range 1 to 30. The 
system default is 2.
Description
Use the oamping interface command to send OAM cells over the specified PVC 
on the specified ATM interface so as to check the link state. If no response is 
received within the specified time, this means that the link is bad, or too busy that 
packets are lost.
Example
# Check the link state of PVC 1/32 on ATM interface 1/0, sending three cells and 
setting timeout period to one second.
<Sysname> system-view
[Sysname] interface atm 1/0
[Sysname-Atm1/0] oamping interface atm 3/0 pvc 1/32 3 1
Ping interface Atm3/0,pvc 0/45, with 5 of 53 bytes of ATM OAM F5 end-to-end
cell(s),
timeout is 1 second(s), press CTRL_C to break
Receive reply from pvc 1/32: time=1 ms
Receive reply from pvc 1/32: time=1 ms
Receive reply from pvc 1/32: time=1 ms 
pvc
Syntax
pvc { pvc-name [ vpi/vci ] | vpi/vci }
undo pvc { pvc-name [ vpi/vci ] | vpi/vci }
View
ATM interface view, PVC-Group view