When restoring the default GARP timers, you are recommended to do that on the 
timers in the order of hold, join, leave, and leaveall.
When configuring GARP timers, note that their values are dependent on each 
other and must be a multiplier of five centiseconds. If the value range for a timer is 
not desired, you may change it by tuning the value of another timer as shown in 
the following table:
Related command:
Example
# Set the GARP join timer to 25 centiseconds, assuming that both the hold timer 
and the leave timer are using the default.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] garp timer join 25 
garp timer leaveall
Syntax
garp timer leaveall timer-value
undo garp timer leaveall
View
System view
Parameter
timer-value: Leaveall timer setting, in the range 65 to 32765 (in centiseconds). 
Note that the setting of the leaveall timer must be a multiple of 5 and must be 
greater than the leave timer settings of all the ports.
Description
Use the garp timer leaveall command to set the leaveall timer of GARP.
Use the undo garp timer leaveall command to restore the default. This may 
fail if the default is less than the setting of the current leave timer.
By default, the setting of the leaveall timer is 1000 centiseconds (that is, 10 
seconds).
A leaveall timer starts upon the start of a GARP application entity. When this timer 
expires, the entity sends a LeaveAll message so that other entities can re-register 
its attribute information and starts another leaveall timer at the same time.
Table 53   Dependencies of GARP timers
Timer 
Lower limit 
Upper limit 
Hold 
10 centiseconds 
Not greater than half of the 
join timer setting 
Join 
Not less than two times the hold timer 
setting 
Less than half of the leave 
timer setting 
Leave 
Greater than two times the join timer 
setting 
Less than the leaveall timer 
setting 
Leaveall 
Greater than the leave timer setting 
32765 centiseconds