3com MSR 20-20 참조 매뉴얼
463
Description
Use the x25 switch svc xot command to add an X.25 switching route whose
forwarding address is XOT channel.
forwarding address is XOT channel.
Use the undo x25 switch svc xot command to delete the specified X.25
switching route.
switching route.
By default, no X.25 switching route is configured.
After configuring the XOT switching command of X.25 SVC, a user can cross IP
network from the local X.25 network to implement the interconnection with the
remote X.25 network. If a user configures the keepalive attribute, the link
detection for XOT will be supported.
network from the local X.25 network to implement the interconnection with the
remote X.25 network. If a user configures the keepalive attribute, the link
detection for XOT will be supported.
Example
# Configure a XOT route and forward the packet whose destination X.121 address
is 1 to the destination address whose IP address is 10.1.1.1.
is 1 to the destination address whose IP address is 10.1.1.1.
<Sysname> system-view
[Sysname] x25 switch svc 1 xot 10.1.1.1
x25 switching
Syntax
x25 switching
undo x25 switching
View
System view
Parameter
None
Description
Use the x25 switching command to enable the X.25 switching function.
Use the undo x25 switching command to disable this function, which will not
affect the established VC switching.
affect the established VC switching.
By default, X.25 packet switching function is disabled.
X.25 packet switching is used to accept packets from an X.25 interface and send
them to a certain interface based on the destination information contained in the
packets. The device with this function can be used as a small-sized packet switch.
them to a certain interface based on the destination information contained in the
packets. The device with this function can be used as a small-sized packet switch.
Table 71 XOT channel parameter option
Option Description
timer seconds
Keepalive timer delay of XOT connection. The timer sends the
keepalive packet upon timeout to detect the connection
availability. Its value ranges from 1 to 3600.
keepalive packet upon timeout to detect the connection
availability. Its value ranges from 1 to 3600.
retry times
Number of maximum retries of sending keepalive. If the number
exceeds times, the XOT connection will be disconnected. Its value
ranges from 3 to 3600.
exceeds times, the XOT connection will be disconnected. Its value
ranges from 3 to 3600.
source interface-type
interface-number
interface-number
Type and number of the interface that initiates the XOT
connection.
connection.