Configuring the Cajun P550 Switch (Layer 2 & Layer 3)
3-4
Cajun P550/P220 Switch Operation Guide
Figure 3-1.  Layer 2/Layer 3 CLI Setup Command Display
Connect to the system with an out-of-band connection using the 10Base-T port on the 
supervisor module front panel for Layer 2 or 10/100Base-T port on the supervisor 
module for Layer 3. 
Figure 3-2.  Cajun P550 Switch
Welcome to Switch Setup. The brief series of questions that
follows will help you to configure this switch. After completing 
this process, you will be able to manage the switch using:
 - the switch-based HTTP server
 - the Element Management System.
Text in [] is the default answer for each questions. To accept
the default, press ENTER.
Would you like to change the super user password [Yes]? Y
Old Password: xxxx
New Password: xxxx
Re-type New Password: xxxx
User password changed succesfully
What do you want the switch manager's console 
Ethernet IP Address to be [0.0.0.0]? 10.0.0.1
What is the subnet mask for your network's 
IP address [0.0.0.0]? 255.255.255.0
What is the IP address of the default gateway for this network segment [0.0.0.0]? 
You can now connect to the switch using the front-panel 
out-of-band 10Base-T connection. This allows you to log in 
using either the embedded web agent or the EMS.
See the Installation and Operation guides for instruction on establishing additional IP 
network connections.
Attach 
Ethernet cable 
here
Attach serial 