Avaya P550 참조 가이드

다운로드
페이지 595
Temperatures
19-6
 Cajun P550/P220 Command Line Interface Reference Guide
Table 19-5.  
Parameters, Keywords, Arguments
 
This example sets the backplane-sensor warning upper temperature to 44° (Celsius).
Cajun(configure)# set temperature backplane-sensor warning upper 
44
Name
Definition
supervisor-slot| 
backplane-sensor| 
cpu-sensor|probe 
These parameters indicate which component of the switch 
is of interest.
warning
Warning is a required parameter indicating that a warning 
limit is being modified.
upper|lower| low-limit
One of these parameters is required  to indicate whether 
the upper, lower, or low-limit warning is being changed.
temperature
Temperature is a required parameter and when the switch 
measures this value on this component, it shuts itself down 
in order to prevent either inconsistent behavior or damage 
to itself or surrounding equipment.  The command checks 
the entered temperature value and ensures that the 
temperature being set is not above 127, and not below -128 
degrees.