Avaya P550 참조 가이드
![Avaya](https://files.manualsbrain.com/attachments/539de53b12b0cfce0bb8cf1e3bb961e969d9f556/common/fit/150/50/0bfb423b07b431ecf5ac095ccde7771f5eac50e962dfba59f8e256280b3d/brand_logo.png)
Temperatures
Cajun P550/P220 Command Line Interface Reference Guide
19-7
.
Display the current temperatures and the configured temperature limits. There is no
reverse mapping to this command. The default values are listed in Table 28-6.
reverse mapping to this command. The default values are listed in Table 28-6.
Table 19-6.
Default Shutdown and Warning Temperatures
Cajun> show temperatures
Slot
1 Sensor Backplane Sensor
CPU Sensor
Shutdown Temperature
50 50 100
Upper Warning Temperature
45 45 85
Current Temperature
29 35 68
Lower Warning Temperature
5 5 5
Low Limit Temperature
0 0 0
Shutdown &
Warning
Temperatures
Warning
Temperatures
Shutdown
Upper
Lower
Warning
Warning
Low Limit
CPU Sensor
100°
85°
5°
0°
All others
50°
45°
5°
0°
To View:
show temperatures