S311 Working error in external input/output 
service [err]
S312 Working error in timer service [err]
S320 PAN/TILT operation error [err]
S330 Failure of fan [err]
S331 Failure of heater [err]
S410 Event service initialization error [crit]
S411 External input/output service 
initialization error [crit]
S412 Timer service initialization error [crit]
Description
cannot work extio [%1][%2][%3] 
(S311)
%1
Error number
%2
Cause of error
%3
Error information
Meaning
An error occurred while the external 
input/output device service was 
running.
Countermeasure
If the problem persists after rebooting, 
the camera is faulty. Arrange for 
servicing.
Description
cannot work timer [%1][%2][%3] 
(S312)
%1
Error number
%2
Cause of error
%3
Error information
Meaning
An internal error occurred in the timer 
service.
Countermeasure
If the problem persists after rebooting, 
the camera is faulty. Arrange for 
servicing.
Description
%1 error occurred. [%2] (S320)
%1
PAN | TILT
%2
Warning details
Meaning
An error occurred during operation or 
stopping of PAN/TILT.
Countermeasure
Check that the camera is not touching 
the dome, etc.
If the error is not caused by problems 
such as contact with peripheral items, 
the camera is faulty. Arrange for 
servicing.
Description
fan [%1] is stopped (S330)
%1
Fan number
Meaning
Detected that the fan is not rotating or 
the rotation speed has significantly 
decreased.
Countermeasure
If the problem persists after rebooting, 
the fan may have failed. Arrange for 
servicing.
Description
HEATER [%1] failure (S331)
%1
Heater number
Meaning
An abnormality was detected when 
using the heater.
Countermeasure
There may be a connection problem 
with the heater unit you attached, so 
check the connections. If the problem 
persists after rebooting, the heater may 
have failed. Arrange for servicing.
Description
event initialization error [%1][%2] 
(S410)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of 
the event service.
Countermeasure
If the problem persists after rebooting, 
the camera is faulty. Arrange for 
servicing.
Description
extio initialization error [%1][%2] 
(S411)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of 
the external input/output device 
service.
Countermeasure
If the problem persists after rebooting, 
the camera is faulty. Arrange for 
servicing.
Description
timer initialization error [%1][%2] 
(S412)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of 
the timer service.
Countermeasure
If the problem persists after rebooting, 
the camera is faulty. Arrange for 
servicing.