Chapter 8. Status Monitoring and Statistics
NETGEAR 8800 User Manual
handling setting appears in parenthesis next to the polling setting. For more information
about the fault handling setting, see
about the fault handling setting, see
In the following truncated output from a NETGEAR 8810 switch, the system health check
setting appears as
setting appears as
SysHealth check: Enabled (Normal)
:
SysName: TechPubs Lab
SysName: XCM8810
SysLocation:
SysContact: support@netgear.com
System MAC: 00:04:96:1F:A2:60
SysHealth check: Enabled (Normal)
Recovery Mode: None
System Watchdog: Enabled
System Health Check Examples: Diagnostics
This section provides examples for using the system health checker on the NETGEAR 8800
series switches. For more detailed information about the system health check commands,
see the chapter on commands for status monitoring and statistics in the NETGEAR 8800
Chassis Switch CLI Manual.
series switches. For more detailed information about the system health check commands,
see the chapter on commands for status monitoring and statistics in the NETGEAR 8800
Chassis Switch CLI Manual.
Example on the NETGEAR 8800 Series Switch
This section describes a series of two examples for:
•
Enabling and configuring backplane diagnostics
•
Disabling backplane diagnostics
Enabling and Configuring Backplane Diagnostics
The following example:
•
Enables backplane diagnostic packets on slot 3
•
Configures backplane diagnostic packets to be sent every 7 seconds
1.
Enable backplane diagnostic packets on slot 3 using the following command:
enable sys-health-check slot 3
When you enable backplane diagnostic packets on slot 3, the timer runs at the default
rate of 5 seconds.
rate of 5 seconds.
2.
Configure backplane diagnostic packets to be sent every 7 seconds using the following
command:
command:
configure sys-health-check interval 7