HP AT519A 사용자 설명서

다운로드
페이지 15
HP Data Center
HP Data Center
HP Data Center
HP Data Center
Environmental Edge Rack
Environmental Edge Rack
Environmental Edge Rack
Environmental Edge Rack
Sensor Array
Sensor Array
Sensor Array
Sensor Array
HP Data Center Environmental Edge Rack Sensor Array contains 3 thermistors to measure rack intake
and 3 thermistors to measure rack exhaust.
NOTE:
NOTE:
NOTE:
NOTE: One year parts only warranty.
NOTE:
NOTE:
NOTE:
NOTE: Must be combined with AT516A Environmental Base Station
HP Data Center
HP Data Center
HP Data Center
HP Data Center
Environmental Edge
Environmental Edge
Environmental Edge
Environmental Edge
Plenum Rate Sensor Array
Plenum Rate Sensor Array
Plenum Rate Sensor Array
Plenum Rate Sensor Array
HP Data Center Environmental Edge Plenum Rated Sensor Array contains 2 plenum rated thermistors
and plenum rated wiring.
NOTE:
NOTE:
NOTE:
NOTE: One year parts only warranty.
NOTE:
NOTE:
NOTE:
NOTE: Must be combined with AT516A Environmental Base Station
HP Data Center
HP Data Center
HP Data Center
HP Data Center
Environmental Edge Air
Environmental Edge Air
Environmental Edge Air
Environmental Edge Air
Pressure Base Station
Pressure Base Station
Pressure Base Station
Pressure Base Station
HP Data Center Environmental Edge Air Pressure Base Station assesses the air pressure differential in
raised floor environments. HP recommends one Air Pressure Base Station per 50 m2 / 500 ft2 of data
center floor space.
NOTE:
NOTE:
NOTE:
NOTE: One year parts only warranty (excluding batteries).
HP Data Center
HP Data Center
HP Data Center
HP Data Center
Environmental Edge Base
Environmental Edge Base
Environmental Edge Base
Environmental Edge Base
Station Gateway
Station Gateway
Station Gateway
Station Gateway
HP Data Center Environmental Edge Base Station Gateway provides the wireless communication with the
HP Data Center Environmental Edge Base Stations and transmits the data to the HP Data Center
Environmental Edge server. HP recommends at least two Base Station Gateways per solution. One Base
Station Gateway pair supports up to 200 base stations. Multiple Base Station Gateway pairs can co-exist
in one data center.
NOTE:
NOTE:
NOTE:
NOTE: One year parts only warranty (excluding batteries).
NOTE:
NOTE:
NOTE:
NOTE: Regional SKU exists
Recommended Base
Recommended Base
Recommended Base
Recommended Base
Configuration
Configuration
Configuration
Configuration
NOTE:
NOTE:
NOTE:
NOTE: The installation of the HP Data Center Environmental Edge recommended base configuration
does not require any data center downtime to implement.
One HP Data Center Environmental Edge Server or server with minimum 4 GB of memory and
250GB of RAID 1 storage
One HP Insight Environmental Observer S/W
One Base Station Gateways per 200 base stations, N+1 configuration
One Environmental Base Station and Plenum Rated Sensor Array per CRAH/CRAC
One Environmental Base Station and Rack Sensor Array per three racks
One Air Pressure Base Station per 500 ft2/50 m2 of data center floor space
QuickSpecs
HP Data Center Environmental Edge and HP Insight
HP Data Center Environmental Edge and HP Insight
HP Data Center Environmental Edge and HP Insight
HP Data Center Environmental Edge and HP Insight
Environmental Observer
Environmental Observer
Environmental Observer
Environmental Observer
Standard Features
DA - 13392   Worldwide — Version 2 — November 16, 2009
Page 4