IBM 3000VA LCD 3U Rack UPS (230V) 53953KX 사용자 설명서

제품 코드
53953KX
다운로드
페이지 22
IBM 3000VA LCD 3U Rack Uninterruptible Power Supply for IBM System x
4
Features
The IBM 3000VA LCD 3U Rack UPS includes the following features and capabilities:
Occupies only 3U of vertical rack space.
Energy efficient at over 95% at 100% load.
Offers six, seven, or 10 receptacles depending on the model:
Model 5395-3AX (100V/120V) has one NEMA L5-20R, two NEMA 5-20R, three IEC 320 C19, and 
two IEC 320 C13 receptacles.
Model 5395-3JX (200V/208V) has two NEMA L6-20R, two IEC 320 C19, and two IEC 320 C13 
receptacles.
Model 5395-3KX (230V) has eight IEC C 320 C13 and two IEC 320 C19 receptacles.
Includes intelligent IBM UPS Manager software that enhances control and manageability.
Compliant with IPv6 for future proofing IP addressing and security.  
Includes a real-time clock that enables precise shutdown and power up of systems in preferred 
sequence and time stamping on event logs to track and record specific power-related occurrences. 
Integrates with IBM Systems Director Active Energy Manager for power and thermal trending analysis 
and management.
Offers load segments allow for individual control of receptacle groups, maximizing run time for critical 
devices. 
Supports an optional network management card (part number 46M4140) for enhanced UPS 
monitoring and control.
Allows dual channel communication through the USB port and optional Network Management Card at 
the same time, which is an effective redundancy feature that maximizes communications flexibility. 
Supports an optional Extended Battery Module (EBM) for increased runtime requirements.
Includes a Remote Emergency Power Off (REPO) port to remotely power off the UPS unit to prevent 
battery operation during a power failure.
Requires a 20A (110V/120V model) or 10A (230V model) single-phase circuit.
Includes hot swap batteries for maximum uptime, availability, and ease of maintenance.
Supports an optional Environmental Monitoring Probe (part number 46M4113) for thermal 
management requirements (temperature and humidity), which requires that the Network Management 
Card be installed.
Uses Advanced Battery Management (ABM) three-stage charging technology significantly extends 
battery service life and optimizes recharge time. The three stages are:
The battery is quickly charged to 90% to make sure the UPS is prepared for the next outage.
1.
ABM finishes charging the battery with a more moderate float charge.
2.
Once the battery is charged, ABM turns the charger off, preventing the batteries from being 
3.
overcharged.