Cisco Cisco ONS 15454 SONET Multiservice Provisioning Platform (MSPP) 릴리즈 노트
2
Release Notes for Cisco ONS 15454 Release 8.5.4
OL-20569-01
Changes to the Release Notes
Changes to the Release Notes
This section documents supplemental information that has been added to the Release Notes for
Cisco ONS 15454 Release 8.5.4 since the production of the Cisco ONS 15454 System Software CD for
Release 8.5.4.
Cisco ONS 15454 Release 8.5.4 since the production of the Cisco ONS 15454 System Software CD for
Release 8.5.4.
Caveats
Review the notes listed below before deploying the Cisco ONS 15454. Caveats with tracking numbers
are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without
tracking numbers are provided to point out procedural or situational considerations when deploying the
product.
are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without
tracking numbers are provided to point out procedural or situational considerations when deploying the
product.
Note
The use of 40WXC units is supported only in the networks running software Release 8.5.1 and later.
Alarms
This section documents caveats for Alarms in Release 8.5. 4.
CSCsv30867—The alarms do not clear after XC side switch
When any VT level alarms are raised, an XC side switch is performed to eliminate the alarm. The alarms
do not clear after XC side switch. The workaround is to reset XC card to clear the alarm. This issue will
be resolved in a future release.
do not clear after XC side switch. The workaround is to reset XC card to clear the alarm. This issue will
be resolved in a future release.
CTC
This section documents caveats for CTC in Release 8.5. 4.
CSCsy14945—CTC cannot manage either nodes of the same version of higher maintenance version,
than its core version
than its core version
CTC cannot manage either nodes of the same version of higher maintenance version, than its core
version. Specifically the nodes are not accessible by CTC. The workaround is to upgrade the CTC core
version or manually clean the CTC jar cache and then ensure no nodes of the specified version above are
encountered. This issue will be resolved in a future release.
version. Specifically the nodes are not accessible by CTC. The workaround is to upgrade the CTC core
version or manually clean the CTC jar cache and then ensure no nodes of the specified version above are
encountered. This issue will be resolved in a future release.
CSCsv14375—Shared secret key corrupt after upgrade
Longer than 16 character shared secret key gets corrupted after an upgrade from 7.20 to 8.54. To avoid
this, use radius server key less than 16 character length before upgrade or:
this, use radius server key less than 16 character length before upgrade or:
On the node with EnableNodeAsFinalAuthenticator attribute enabled, do the following as workaround:
1.
Launch CTC.