Release Notes for Cisco ONS 15454 Release 8.5.4
OL-20569-01
  Caveats
2.
Delete the corrupted secret key record in CTC (node view->Provisioning->Security->RADIUS 
Server).
3.
Recreate it with an appropriate key.
This issue will be resolved in a future release.
Data I/O Cards
This section documents caveats for Data I/O Cards in Release 8.5. 4.
CSCsx49481—Fiber SFP port reports CARLOSS Alarm in CEMR-6 card
Plug-out copper SFP in OOS,DSBLD state and plug-in Fiber SFP and move the port state to IS. Fiber 
SFP port reports CARLOSS Alarm in CEMR-6 card. To recover from CARLOSS, plug-out and plug-in 
Fiber SFP again. This issue will be resolved in a future release.
CSCsy16814—Traffic Drop is observed when port state change from OOS-DSBLD to IS
Traffic Drop is observed when port state change from OOS-DSBLD to IS. The workaround is to perform 
IS->OOS-> IS transition until problem is fixed. This issue will be resolved in a future release.
CSCsx75218—VC12 VCAT circuit members may not come-up and report LOP alarm
Create VC4-2c/ VC4-3c/ VC4-4c/ VC4-8c/ VC4-16c or any of the CCAT and the delete the CCAT 
circuit. Create VC12 VCAT circuit using the same VC4 members as previously deleted CCAT circuits. 
Some VC12 VCAT circuit members may not come-up and report LOP alarm. The workaround is to 
hard-reset CEMR-10/CEMR-6/MLMR-10 cards. This issue will be resolved in a future release.
DWDM
This section documents caveats for DWDM in Release 8.5. 4.
CSCsx17868—The MXP-MR-10DME card continuously reboots after FPGA upgrade
The MXP-MR-10DME card continuously reboots after FPGA upgrade. Forcing an FPGA upgrade on an 
MXP-MR-10DME results in a status where the card reboots continuously. The workaround is to reset 
the card. This issue will be resolved in a future release.
CSCsu81842—Circuit not created through add and drop node with by-pass patchcords
The OCHNC circuit is not created through channel add and drop node with by-pass patchcords. When 
the traffic matrix of the network requires BYPASS connection between AD-XC cards, the APC domain 
is not properly discovered. The workaround is to remove the bypass patchcords in the node and create 
two separated OCH-NC circuits. This issue will be resolved in a future release.