Cisco Cisco D9824 Advanced Multi Decryption Receiver 설치 가이드

다운로드
페이지 336
 
 
 
Configuring System Settings 
 
78-4039426-01 Rev D 
195 
 
Note: No is a read only value that indicates the setting is Yes, but is currently 
being suppressed because the alarm is disabled (Enb is set to No). 
8  If current alarm is enabled, set Relay to Yes for the rear panel alarm relay to be 
triggered when the alarm is set or cleared. 
Note: No is a read only value that indicates the setting is Yes, but is currently 
being suppressed because the alarm is disabled (Enb is set to No). 
9  Click Apply
 
To Set Up Warnings 
1  
From the Setup - Alarm Setup page, click on the Warning Setup link at the 
bottom left hand corner of the page. The Setup - Warning Setup page is 
displayed. 
 
2  Select Enable Alarm/Warning Front Panel Reminder and the warning flashes on 
the LCD display for a two-second interval every 10 seconds. The warning will 
continue to flash periodically until it is either cleared or the Enable 
Alarm/Warning Front Panel Reminder
 is de-selected. 
3  The Warning Setup section displays a list of the warning messages. For more 
information on warning messages, refer to Messages (see "D9824 Alarm 
Messages
" o
n page 222).  
4  Set Enable/Disable to Yes and the warning message will be reported. Set to No 
and the warning is disabled and the Relay and Trap settings are ignored. 
Note: Enable/Disable must be set to Yes for the Relay and Trap settings to be 
functional.