Installing the Cisco VCS
Installing the Cisco VCS
Package contents
To avoid damage to the unit during transportation the Cisco VCS is delivered in a special shipping box, 
which should contain the following components:
 
Cisco VCS unit
 
rack ears, screws and Torx driver
 
rubber feet
 
cables:
 
power cables
 
Ethernet cable
 
shielded serial cable
Report any discrepancies to your Cisco representative immediately.
We recommend that the shipping box is kept in case the Cisco VCS needs to be returned.
Before you start
IMPORTANT: Before installing the Cisco VCS, you must read the safety information at 
.
Preparing the installation site
Before installing the Cisco VCS:
 
Ensure that the Cisco VCS is accessible and that all cables can be easily connected.
 
Ensure that the power outlet is near to the Cisco VCS and is easily accessible.
 
To ensure adequate ventilation, leave a space of at least 10cm (4 inches) behind the unit’s rear 
panel and 10cm (4 inches) in front of the front panel.
 
The Cisco VCS has side air intakes and rear air exhaust. A check should be made to ensure 
there is sufficient ventilation, particularly at the sides.
 
Ensure that other devices are not exhausting directly into the air intake on  the Cisco VCS. 
Note that Codian MCU airflow is from right to left, so be especially careful if racking them to 
the right of Cisco VCS.
Figure 1: Cisco VCS ventilation
 
The room in which you install the Cisco VCS should have an ambient temperature between 0ºC and 
35ºC (32ºF and 95ºF) and between 10% and 90% non-condensing relative humidity.
 
Use a grounded AC power outlet for the Cisco VCS.
Preparing the unit
 1.  Unpack the unit.
 2.  Mount the rack ears (using a Torx T10 driver) or rubber feet. 
 3.  Turn the unit back on its feet or mount it in the rack.
VCS Getting Started Guide
Page 4 of 12