Cisco Cisco UCS C210 M1 General-Purpose Rack-Mount Server 데이터 시트

다운로드
페이지 86
Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)
82
TECHNICAL SPECIFICATIONS
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
Environmental Specifications
The power specifications for the C220 M4 server are listed in 
Power supply standby voltage
12 VDC
Efficiency rating
Greater than or equal to  92% at 50% load 
Form factor
RSP2
Input connector
3 wire Connector (Molex MINIFIT SR. R/A)
Table 46  UCS C220 M4 LFF Environmental Specifications
Parameter
Minimum
Temperature operating
41 to 95° F (5 to 35° C)
derate the maximum temperature by 1°C per every 
 
1000 ft. (305 m) of altitude above sea level
Temperature nonoperating
–40 to 149°F (–40 to 65° C)
Humidity (RH) operating
10 to 90%, non-condensing at 82° F (28° C)
Humidity (RH) nonoperating
5 to 93% at 82° F (28° C)
Altitude operating
0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating
0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure 
A-weighted per ISO7779 LWAd (Bels) 
Operation at 73°F (23°C) 
5.4
Sound Pressure level, Measure 
A-weighted per ISO7779 LpAm (dBA) 
Operation at 73°F (23°C) 
37
Table 45  UCS C220 M4 LFF 1050 W (DC) Power Supply Specifications  (continued)
Description
Specification