Chapter 1      Problems and Symptoms
Silent Monitor Problems (IPCC Only)
1-28
Cisco ICM Software CTI OS Troubleshooting Guide Release 6.0(0)
The Phone is not sending the packets because the PC port is deactivated 
(check Network settings on the phone, note, in this case the system is off 
the network). Also, future CallManager versions might support a setting 
on the phone configuration page to enable/disable voice packets on the 
PC port of the phone.
The specific NIC card in the PC has problems accessing voice packets. 
Check NIC card properties and configuration. Some NIC cards require 
special configuration to capture packets off a different VLAN. If 
possible, try another NIC card (or system) to verify this is the case.
Symptom
After just installing CTI OS Server Release 5.1 or later, CTI OS Agent 
Desktop, and CTI OS Supervisor Desktop for IPCC Enterprise (both with the 
Silent Monitor option), Silent Monitor does not work.
Possible Cause
Make sure that the agent that is being monitored has the agent 
desktop system plugged into the back of the hardphone. In a duplex CTI OS 
environment, make sure that the CTI OS servers are configured as peers during 
the CTI OS server install. In a lab environment try temporarily shutting down 
one CTI OS server and try again. If it still does not work, please read the other 
symptom discussions in this section.
Symptom
The Silent Monitor Button is not enabled on the CTI OS Supervisor 
Desktop for IPCC Enterprise.
Possible Cause
Possible reasons:
When the Client was installed, the Silent Monitor option was not 
checked. Please reinstall and check the Silent Monitor option
The supervisor is logged on to a connection profile (See section about 
connection profiles in the Systems manager guide) has the registry key 
“IPCCSilentMonitorEnabled” set to 0 (1 means enabled and is the 
default) – either change this key or use a different connection profile
The agent currently selected in the Real-Time grid is not logged on
The CTI OS Server this client is currently connected to does not support 
Silent Monitor (i.e., it is a release prior to Release 5.1)
The supervisor is not logged on