Cisco Cisco Aironet 1522 Lightweight Outdoor Mesh Access Point 설치 가이드

다운로드
페이지 70
 
48
Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
78-18269-04
  Powering the Access Point
If your access point contains a backup battery pack, you must press the reset button for 10 seconds or 
more (see the
 
.)
Step 3
When using the streetlight power tap adapter (AIR-PWR-ST-LT-R3P=), ensure that the access point is 
mounted within 3 ft (1 m) of the outdoor light control. For mounting instructions, refer to the 
Step 4
Ensure a 6-AWG ground wire is attached to the access point (see 
) and connected to the 
streetlight pole (for instructions see 
Figure 31
Using the Streetlight Power Tap Adapter 
Step 5
Refer to 
. The streetlight power tap adapter uses a 3-pronged LC-10 twist-lock adapter that is 
placed between the outdoor light control and its fixture. The LC-10 twist-lock adapter is designed to be 
used with LC-10 listed outdoor light controls operating at 100 to 480 VAC, 50 to 60 Hz.
Step 6
Disconnect the outdoor light control from its fixture.
Step 7
Verify that the voltage available at the fixture is between 100 and 480 VAC, 50 to 60 Hz.
Step 8
Turn off power to the fixture at the designated circuits.
Caution
When installing the streetlight power tap adapter to the access point AC power connector, always 
connect the access point end of the cable FIRST. When removing the streetlight power tap adapter, 
always disconnect the access point end of the cable last
Note
Ensure that your antennas are connected to the access point before you apply power to the access 
point.
1
Outdoor light control
3
6-AWG copper grounding wire
2
Streetlight power tap adapter
231524
1
2
3