SPECIFICATIONS, REGULATORY, and SECURITY
Physical and Environmental Parameters
Parameter
3D7010/7020/7030
3D7110/7120
3D7115/7125, AMP7150
Form factor
1U, half-rack width
1U
Dimensions (D x W x H)
Single chassis: 12.49” x 7.89” x 1.66” (31.74 cm x 20.04 cm x 4.21 cm)
2-Chassis Tray: 25.05” x 17.24” x 1.73” (63.62 cm x 43.8 cm x 4.44 cm)
21.6 x 19.0 x 1.73 inches (54.9 x 48.3 x 4.4 cm)
Weight (max installed)
Chassis: 7 pounds (3.17 kg)
Single chassis and power supply in tray: 17.7 pounds (8.03 kg)
Double chassis and power supplies in single tray: 24.7 pounds (11.2 kg)
29.0 pounds (13.2kg)
Copper 1000BASE-T
Gigabit copper ethernet fail-open interfaces in a paired configuration
Cable and distance: Cat5E at 50m
Gigabit copper ethernet fail-open interfaces in a paired configuration
Cable and distance: Cat5E at 50m
Fiber 1000BASE-SX
Not applicable
Fiber bypass with LC connectors
Cable and distance: SX is multimode 
fiber (850nm) at 550m (standard)
Not applicable
Copper 1000BASE-T SFP
Not applicable
Not applicable
Gigabit copper ethernet non-bypass 
interfaces in a paired configuration
Cable and distance: Cat5E at 50m
Fiber 1000BASE-SX SFP
Not applicable
Not applicable
Fiber non-bypass with LC connectors
Cable and distance: SX is multimode 
fiber (850nm) at 550m (standard)
200m (656 ft) for 62.5μm/125μm fiber
 
500m (1640 ft) for 50μm/125μm fiber
Fiber 1000BASE-LX SFP
Not applicable
Not applicable
Fiber non-bypass with LC connectors
Cable and distance: LX is single mode 
fiber (1310nm) at 10km for 9μm/125μm 
fiber (standard) 
Power supply
200W AC power supply
Voltage: 100VAC to 240VAC nominal (90VAC to 264VAC maximum)
Current: 2A maximum over the full range
Frequency range: 50/60 Hz nominal (47Hz to 63Hz maximum)
450W dual redundant (1+1) AC power supplies
Voltage: 100VAC to 240VAC nominal (85VAC to 264VAC maximum)
Current: 3A maximum for 90VAC to 132VAC, per supply
1.5A maximum for 187VAC to 264VAC, per supply
Frequency range: 47Hz to 63Hz
Operating temperature
0°C to 40°C (32°F to 104°F)
5°C to 40°C (41°F to 104°F)
Non-operating temperature
-20°C to 70°C (-4°F to 158°F)
-20°C to 70°C (-4°F to 158°F)
Operating humidity
5% to 95%, noncondensing
Operation beyond these limits is not guaranteed and not recommended.
5% to 85%, non-condensing
Operation beyond these limits is not guaranteed and not recommended.
Non-operating humidity
0% to 95%, non-condensing 
Store the unit below 95% non-condensing relative humidity. Acclimate 
below maximum operating humidity at least 48 hours prior to placing 
the unit in service.
5% to 90%, non-condensing with a maximum wet bulb of 28°C (82°F) at 
temperatures from 25°C to 35°C (77°F to 95°F)
Store the unit below 95% non-condensing relative humidity. Acclimate below 
maximum operating humidity at least 48 hours prior to placing the unit in 
service.
Altitude
0 ft (sea level) to 5905 ft (0 to 1800m)
0 ft (sea level) to 5905 ft (0 to 1800m)
Cooling requirements
682 BTU/hour
You must provide sufficient cooling to maintain the device within its 
required operating temperature range. Failure to do this may cause a 
malfunction or damage to the device.
900 BTU/hour
You must provide sufficient cooling to maintain the device within its required 
operating temperature range. Failure to do this may cause a malfunction or 
damage to the device.
Acoustic noise
53 dBA when idle. 62 dBA at full processor load.
64 dBA at full processor load, normal fan operation 
Meets GR-63-CORE 4.6 Acoustic Noise
Operating shock
No errors with half a sine wave shock of 5G (with 11 msec. duration)
Complies with Bellecore GR-63-CORE standards
Airflow
20 ft
3
 (0.57m
3
) per minute
Airflow through the device enters at the front and exits at the rear, with 
no side ventilation.
140 ft
3
 (3.9m
3
) per minute
Airflow through the device enters at the front and exits at the rear with no side 
ventilation.
Regulatory Conformance
This Sourcefire device conforms to multiple national and international standards.  For a full list of regulatory compliance, see the 
Sourcefire 3D System Installation Guide
.
Security Considerations
Before you install your device, Sourcefire recommends that you consider the following:
Locate your device in a lockable rack  within a secure location that prevents access by unauthorized personnel.
• 
Allow only trained and qualified personnel to install, replace, administer, or service the device.
• 
Always connect the management interface to a secure internal management network that is protected from unauthorized access.
• 
Hardware Specifications
7000 SERIES
Quick Start Guide - 7000 Series Devices
2014-5.3-3
Page 8 of 8
9770 Patuxent Woods Drive
Columbia, MD  21046  USA
800.917.4134 | +1.410.423.1901
support@sourcefire.com
©2014 Cisco and/or its affiliates.  
All rights reserved.
WARNING!
This Sourcefire device should be installed and maintained by 
qualified personnel only. Keep in mind the following safety 
information to avoid system damage or personal injury:
Remove all factory packaging before using the device.
• 
Provide adequate ventilation to prevent overheating.  Do not 
• 
cover or block vents, or otherwise enclose the device.  
The device must be properly grounded when connecting power 
• 
to the power outlet.
At all times, keep the chassis area free from dust.
• 
Lifting the chassis for rack installation may require two people, 
• 
as the unit is heavy.
To avoid electrical shock, do not open or remove the chassis 
• 
covers or metal parts without proper instruction.
!