Cisco Cisco Aironet 602 OfficeExtend Access Point 기술 매뉴얼

다운로드
페이지 4
Split Tunnel with OEAP Access Points
Configuration Example
Document ID: 117540
Contributed by Ishaan Sanji, Cisco TAC Engineer.
Mar 18, 2014
Contents
Introduction
Prerequisites
     Requirements
     Components Used
Network Diagram
     The Packet Flow Process
Configure
     Limitations
Verify
Troubleshoot
Introduction
This document describes the case where the split tunnel access−points, with the controller code Release 7.5,
allow clients (that connect to the corporate SSID) to connect to the corporate resources and access local
resources simultaneously. It is available for clients that connect through the corporate SSID and the remote
LAN. This feature presently supports the split tunneling for printers with the common printer ports such as
PDL (port:9100), IPP (port:631), MFP (port: 9303), LPR (port:515), PSUS4 (port:34443), and Generic printer
server (port:35).
Prerequisites
Requirements
There are no specific requirements for this document.
Components Used
The information in this document is based on these software and hardware versions:
Wireless LAN Controller (WLC) that runs Release 7.5 and later
• 
OEAP−600 series Access Points (AP)
• 
The information in this document was created from the devices in a specific lab environment. All the devices
used in this document started with a cleared (default) configuration. If your network is live, make sure that
you understand the potential impact of any command.