Cisco Cisco Aironet 350 Access Points 릴리즈 노트

다운로드
페이지 10
 
4
Caveats
OL-2381-01
Caveats
Use the Authenticator Configuration page in access point firmware version 11.06a to select the draft of 
the 802.1x protocol the access point’s radio should use. Follow these steps to set the draft for your access 
point:
Step 1
Browse to the Authenticator Configuration page in the access point management system.
a.
On the Summary Status page, click Setup.
b.
On the Setup page, click Security.
c.
On the Security Setup page, click Authentication Server.
Step 2
Use the 802.1x Protocol Version (for EAP authentication) pull-down menu to select the draft of the 
802.1x protocol the access point’s radio should use. Menu options include:
Draft 7—No radio firmware versions compliant with Draft 7 have LEAP capability, so you 
should not need to select this setting.
Draft 8—Select this option if LEAP-enabled client devices that associate with this access point 
use radio firmware versions 4.13, 4.16, or 4.23.
Draft 10—This is the default setting in access point firmware versions 11.06 and later. Select 
this option if client devices that associate with this access point use Microsoft Windows XP EAP 
authentication or if LEAP-enabled client devices that associate with this access point use radio 
firmware version 4.25 or later.
Step 3
Click Apply or OK to apply the setting. The access point reboots.
Caveats
Resolved Caveats 
The following caveats have been resolved in firmware version 11.06a:
Resolved: CSCdw63011. An error can occur with management protocol processing. Please use this 
URL for further information:
Resolved: CSCdw63031. An error can occur with management protocol processing. Please use this 
URL for further information:
The following caveats were resolved in firmware version 11.06 and are also resolved in version 11.06a:
Resolved: Successful firmware distribution reports error (CSCdt31501). When distributing 
firmware to an access point running firmware version 11.01 or later, the distribute status on the 
distributing access point or bridge reports an error even when the distribution is successful.
Resolved: Must restart unit twice to enable standby mode (CSCds36123).