13
OL-19762-01
  Cisco Aironet 1524SB Outdoor Mesh Access Point Hardware Addendum
Figure 5
Reset Button Location
Removing and Replacing the Reset Button Cover
The access point reset button is recessed in a small hole, sealed with a Phillips screw cover and rubber 
gasket. To remove and replace the reset button cover, follow these steps:
Step 1
Use a Phillips screwdriver to remove the reset button cover. Be careful not to lose the screw and rubber 
gasket.
Step 2
Use a straightened paper clip to perform the intended action (reset the access point or disable the 
battery).
Step 3
Replace the rubber gasket and start the reset button cover into the threaded hole.
Step 4
Use a Phillips screwdriver to tighten the cover to 22 to 24 in. lbs (2.49 to 2.71 Nm).
1
Reset button