Cisco Cisco WAP571 Wireless-AC N Premium Dual Radio Access Point with PoE 관리 매뉴얼

다운로드
페이지 192
Captive Portal
Instance Configuration
Cisco WAP571/E Administration Guide
159
11
Maximum Bandwidth Upstream—Enter the maximum upload speed, in 
megabits per second, that a client can transmit traffic when using the captive 
portal. This setting limits the bandwidth used to send data into the network. 
The range is from 0 to 1300 Mbps. The default is 0.
Maximum Bandwidth Downstream—Enter the maximum download speed, 
in megabits per second, that a client can receive traffic when using the 
captive portal. This setting limits the bandwidth used to receive data from 
the network. The range is from 0 to 1300 Mbps. The default is 0.
STEP  5
Click Save User. The changes are saved to the Startup Configuration.
To delete a local user:
STEP 1
Select Captive Portal > Local Groups/Users.
STEP  2
In the Local Users Settings area, choose the user that you want to delete.
STEP  3
Check the Delete User option.
STEP  4
Click Delete User. The changes are saved to the Startup Configuration.
Instance Configuration
You can create up to two CP instances; each CP instance is a defined set of 
instance parameters. Instances can be associated with one or more VAPs. 
Different instances can be configured to respond differently to users as they 
attempt to access the associated VAP.
NOTE
Before you create an instance, review these bullets first:
Do you need to add a new VAP? If yes, go to 
 page to add a VAP.
Do you need to add a new group or new user? If yes, go to 
 
page to add a group or user.
To create a CP instance and configure its settings: