Cisco Cisco Prime Central 1.5 설치 가이드

다운로드
페이지 97
Integrating SpiderNet with Prime Central
Procedure
Step 1
From the Fault Source Management portlet, click Add to add the Fault Source details.
The Add New Fault Source dialog box appears.
Step 2
Enter the Fault Source Type from the drop-down as SpiderCloud and specify the Fault Source details in the appropriate
fields.
Step 3
Click OK.
For more Information about how to add a Fault Source and the field descriptions, refer to the section Adding a Fault
Source 
in the
After the SpiderNet Fault Source is added, SpiderNet is registered with Prime Central as a domain manager
instance.
Note
Configuring Prime Central as Trap Listener in SpiderNet to Receive Traps
Procedure
Step 1
Login to SpiderNet server GUI.
Step 2
Create a SNMP Managers Group:
a) Choose Administration Northbound Interface New SNMP Manager Group.
b) Enter Prime Central details:
• In Port field, enter 1162 port number.
• In Host Names or IP Addresses field, enter Prime Central FM server hostname or IP address.
• Select Alarm Forwarding checkbox and in SNMP Version choose V2C. In Community, enter Public.
• Uncheck Enable the Heartbeat Trap check box, as this trap is not supported in Prime Central.
• Click OK.
Step 3
Configure Events:
a) Choose Administration Fault Management Events Configuration.
b) Select Forward to SNMP check box and choose Prime Central SNMP Manager group in the drop-down.
c) Click Save.
Step 4
Configure a Trap Target:
a) Choose Network Control SN. Right click on SN , go to Show Configuration Advanced Event Management
Target. Right click on Target, and click Add Target.
• Provide Target Index and click OK.
• Select SNMP Trap in newly created index and enable SNMP Trap. In IP Address field, enter Management Server
IP Address.
69