Installing the Enhanced Digital Reverse Modules in the Node
2-7
Removing the Status Monitor Module,
Continued
2.
Disconnect the cable that is attached to the Tx (transmitter) connector on the
status monitor module, from the Status Monitoring Input on the RF launch
amplifier module.
3.
Disconnect the cable that is attached to the Rx (receiver) connector on the
status monitor module, from the J8 connector location on the J8 jumper
board.
4.
Disconnect the ribbon cable that is attached to the status monitor module
from the Status Monitor module connection on the optical interface board.
5.
Remove the status monitor module from the fiber management tray bracket.
Note: Gently pull the fiber management tray bracket sides (closest to the RF
Note: Gently pull the fiber management tray bracket sides (closest to the RF
section of the housing) out to allow the pins to be removed from the holes of
the status monitor module.