Cisco Prisma II bdr Dig Rev 2 1 Dual Mux Sys for High Density Installations 설치 가이드

다운로드
페이지 76
78-741939-01 Rev C 
Installing the Enhanced Digital Reverse Modules in the Node 
 
2-7 
Removing the Status Monitor Module,
 Continued 
 
2. 
Disconnect the cable that is attached to the Tx (transmitter) connector on the 
status monitor module, from the Status Monitoring Input on the RF launch 
amplifier module. 
3. 
Disconnect the cable that is attached to the Rx (receiver) connector on the 
status monitor module, from the J8 connector location on the J8 jumper 
board. 
 
4. 
Disconnect the ribbon cable that is attached to the status monitor module 
from the Status Monitor module connection on the optical interface board. 
5. 
Remove the status monitor module from the fiber management tray bracket. 
Note:  Gently pull the fiber management tray bracket sides (closest to the RF 
section of the housing) out to allow the pins to be removed from the holes of 
the status monitor module.