Cisco Headend System Release 3.2 관리 매뉴얼
Chapter 1 Staging Preparation
36
4024836 Rev D
7 Click Add. The MAC Address of the CableCARD module moves to the
Associated DHCTs column.
8 Repeat steps 6 and 7 for each CableCARD module you want to add to the group.
9 When you are finished adding CableCARD modules to the group, click Save.
9 When you are finished adding CableCARD modules to the group, click Save.
Notes:
The CableCARD module should be connected to the network within 2 hours
of creating or adding it to a test group. If the CableCARD module is not
connected within 2 hours, then the CableCARD module does not receive a
group assignment until the DNCS database cycles through all in-service
devices at a rate of approximately one device per second. Depending on the
number of devices in your system, this process could take a significant
amount of time.
If the CableCARD module has an Administrative State of Out of Service, the
CVT Group ID message will not be sent by the PassThru process to that
CableCARD module. To check the Administrative State of the CableCARD
module, see DHCT and CableCARD Module Administrative Status (on page
10 Confirm that the CableCARD module was successfully placed into the test group
by displaying the CableCARD module diagnostic screens and looking at the
Group ID field. This group ID should match the Group ID field displayed on the
Set Up a DHCT Group window on the DNCS.
Note: The Group ID on the CableCARD module is in hexadecimal format. The
Note: The Group ID on the CableCARD module is in hexadecimal format. The
Group ID on the DNCS is in decimal format. You might need to convert the
Group ID to verify this step.
11 Do the Group ID values on the diagnostic screen and DNCS match?
If yes, go to Verify CableCARD Connectivity (on page 36).
If no, contact Cisco Services.
Verify CableCARD Connectivity
Before you add a CableCARD module to a CVT group, you need to verify that the
Before you add a CableCARD module to a CVT group, you need to verify that the
connectivity state on the DNCS matches the connectivity state of the CableCARD
module.