Adobe photoshop cs2 사용자 설명서
482
ADOBE PHOTOSHOP CS2
User Guide
Minimum Depth
Specifies the minimum depth to which paint can penetrate when Depth Control is set to Fade, Pen
Pressure, Pen Tilt, or Stylus Wheel and Texture Each Tip is selected.
Depth Jitter and Control
Specifies how the depth varies when Texture Each Tip is selected. To specify the
maximum percentage of jitter, enter a value. To specify how you want to control the depth variance of brush marks,
choose an option from the Control pop-up menu:
choose an option from the Control pop-up menu:
•
Off
Specifies no control over the depth variance of brush marks.
•
Fade
Fades from the Depth Jitter percentage to the Minimum Depth percentage in the specified number of steps.
•
Pen Pressure, Pen Tilt, or Stylus Wheel
Varies the depth based on the pen pressure, pen tilt, or position of the pen
thumbwheel.
See also
Dual brushes
A dual brush uses two tips to create brush marks. Set options for the primary tip in the Brush Tip Shape section of
the Brushes palette. Select a second brush tip from the Dual Brush section of the Brushes palette and set any of the
following options.
the Brushes palette. Select a second brush tip from the Dual Brush section of the Brushes palette and set any of the
following options.
)
Brush strokes created with a single tip (left) and with dual tips (right
Mode
Sets a blending mode to use when combining brush marks from the primary tip and the dual tip. (See “List
Diameter
Controls the size of the dual tip. Enter a value in pixels, drag the slider, or click Use Sample Size to use the
original diameter of the brush tip. (The Use Sample Size option is available only if the brush tip shape was created by
sampling pixels in an image.)
sampling pixels in an image.)
Spacing
Controls the distance between the dual tip brush marks in a stroke. To change the spacing, type a number
or use the slider to enter a percentage of the tip diameter.
Scatter
Specifies how dual tip brush marks are distributed in a stroke. When Both Axes is selected, dual tip brush
marks are distributed in a radial direction. When Both Axes is deselected, dual tip brush marks are distributed
perpendicular to the stroke path. To specify the maximum percentage of scattering, type a number or use the slider
to enter a value.
perpendicular to the stroke path. To specify the maximum percentage of scattering, type a number or use the slider
to enter a value.
Count
Specifies the number of dual tip brush marks applied at each spacing interval. Type a number, or use the slider
to enter a value.