Adjustments
70269701
62
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Airflow Switch
The airflow switch is set at the factory for proper 
operation. No adjustment necessary.
The airflow switch operation may be affected by 
shipping tape still in place, lack of make-up air, or an 
obstruction in the exhaust duct. These should be 
checked and the required corrective action taken 
before attempting to adjust airflow switch.
IMPORTANT: Airflow switch vane must remain 
closed during operation. If it opens and closes 
during the drying cycle, this indicates insufficient 
airflow through the tumbler. If switch remains 
open, or pops open and closed during the cycle, the 
heating system will shut off. The cylinder and fan 
will continue to operate even though the airflow 
switch is indicating insufficient airflow.
Door Strike
The door strike must be adjusted to have sufficient 
tension to hold loading door closed against force of the 
load tumbling against it. There is proper adjustment of 
pull force when 8 to 15 pounds (35.6 N – 66.7 N) is 
required to open door.
To adjust, open door, loosen acorn nut, and turn door 
strike screw in or out as required. Retighten acorn nut.
Figure 17 
WARNING
The tumbler must not be operated if the 
airflow switch does not operate properly. 
Faulty airflow switch operation may cause 
an explosive gas mixture to collect in the 
tumbler.
W072
TMB997N
1
Door Strike Screw
2
Acorn Nut
TMB997
1
2