Allen-Bradley 160-Series AC Drives
41
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Control Terminal Blocks Description and 
Control Logic
Control Terminal Block (TB3) Function
Input Mode Parameter
The control terminal functions are determined in part 
by the Input Mode parameter #46. Changing this 
parameter affects the function of some terminals. All 
machines equipped with A-B 160 drives use Input 
Mode “1”.
NOTE: If Input Mode is changed, power must be 
cycled to the drive for the change to take effect.
Speed Selection
Motor speeds on digitally-controlled AC drives are 
controlled by solid state or relay switch closure inputs 
to SW1, SW2, and SW3 in conjunction with STR and 
STF (direction) inputs. Refer to Figure 24 and 
Table 25.
Figure 24 
Control Terminal Block Designations
Table 25 
WARNING
To reduce risk of electric shock, severe 
injury or death, allow machine power to 
remain off for three minutes minimum prior 
to working in and around AC drive. Proceed 
with caution.
W662
CAUTION
The controller is supplied with an internal 
power supply. Dry contacts or open 
collectors are required for discrete control 
inputs. If an external voltage is applied, 
component failure could occur.
W663
Terminal
Number
Signal
Machine Use
1, 3
SW1
Preset Speed Input 
#1
2, 3
SW2
Preset Speed Input 
#2
4, 3
SW3
Preset Speed Input 
#3
5, 3
STR
Reverse Motion
6, 7
STF
Forward Motion
8, 7
Stop
Safety Device
9, 10
Programmable 
Output 1 Normally 
Closed
Not Used
10, 11
Programmable 
Output 1 Normally 
Open
Balance Output
PHM654N
Washer-Extractor
Control Hardware
Drive Hardware
Solid State Switch
TB3
Input Mode = “1” Parameter #46
Typical Configuration
1 - SW1 - Preset Input 1
2 - SW2 - Preset Input 2
3 - Common
4 - SW3 - Preset Input 3
5 - STR - Start Reverse
6 - STF - Start Forward
7 - Common
8 - Stop
9 - Not Used
Detection
10,11 - Output - Balance
Jumper,*
Switch,
or Relay
* on older models