Alliance Laundry Systems 1305 사용자 설명서

다운로드
페이지 111
Allen-Bradley 160-Series AC Drives
53
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Viewing a Display Group
(Parameters #1 – 16 for Series A & B or 
Parameters #1 – 19 for Series C)
1. Install PKM on A-B 160 drive. Refer to 
“Installation/Removal”.
2. Turn on machine power.
3. Select the desired parameter by pressing the Up 
and Down arrow keys 
. The parameter 
value is shown in the last four digits of the 
display.
Viewing a Program Group 
(Parameters #30 – 80 for Series A & B or 
Parameters #30 – 86 for Series C)
1. Install PKM on A-B 160 drive. Refer to 
“Installation/Removal.”
2. Turn on machine power.
3. The PKM begins in Display. Press the ESC key 
to enter the Program Group.
NOTE: Confirmation of the mode is presented by a 
decimal point after the second parameter digit.
4. Parameter #30 should be displayed if entering the 
program group for the first time.
5. From this point, parameters #30 – 80 can be 
viewed by pressing the Up and Down arrow keys 
.
6. To exit the Program Group, press the 
ESC key 
.
Display Mode Parameter Set
0
1
0.
0
3
0.
5.
0
CAUTION
Users are prohibited from changing 
parameter values unless specifically 
instructed by the washer-extractor 
manufacturer. Modification to parameter 
values may present potential harmful 
operating conditions for both hardware and 
personnel.
W673
ESC
ESC
1
Output Frequency
2
Output Voltage
3
Output Current
4
Output Power
5
Bus Voltage
6
Frequency Command
7
Last Fault
8
Heatsink Temperature
9
Controller Status
10
Controller Type
11
Control Version
12
Input Status
13
Power Factor Angle
14
Memory Probe Address
15
Preset Status
16
Balance Angle
*17
Fault Buffer 0
*18
Fault Buffer 1
*19
Fault Buffer 2
Table 33