Alliance Laundry Systems 1305 사용자 설명서

다운로드
페이지 111
Allen-Bradley 1305-Series AC Drives
73
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
AC Drive Diagnostics/Parameter 
Viewing
Human Interface Module (HIM or 
Parameter Unit)
Installation/Removal
The following are instructions for installing/removing 
the Human Interface Module (P/N F370597) on the 
drive for parameter viewing and basic troubleshooting. 
The parameter unit (F370597) and instructions 
(F232120) are included in the Parameter Kit (P/N 
F744501).
Installing the HIM
1. Remove power from machine at main 
disconnect. Delay approximately three minutes.
2. Lower the hinged panel located below the HIM.
3. Slide blank panel cover toward base of drive and 
remove it. Place top edge of HIM approximately 
1/2 inch from top edge of the cover. Push inward 
on bottom of HIM and slide HIM up (toward the 
top of the drive) into position.
Removing the HIM
1. Remove power from machine at main 
disconnect. Delay approximately three minutes.
2. Lower hinged panel located below HIM.
3. Press retaining lever located directly beneath 
HIM. Slide HIM downward and remove it from 
drive.
4. Reinstall blank panel cover. Close hinged panel.
External HIM Connection
The HIM unit can be installed using an adapter cable 
(P/N P370716). This method of attaching the HIM 
uses an external connector shown in Figure 44. The 
HIM unit operates in the same manner in this 
configuration.
NOTE: If the HIM is removed while the drive is 
powered, a communication fault (Serial Fault #10) 
will occur and the drive will be disabled. Cycle 
power to the drive to reset the fault condition.
Figure 44 
CAUTION
Users are prohibited from changing 
parameter values unless specifically 
instructed by the washer-extractor 
manufacturer. Modification to parameter 
values may present potential harmful 
operating conditions for both hardware and 
personnel.
W673
WARNING
To reduce risk of electric shock, severe 
injury or death, allow machine power to 
remain off for three minutes minimum prior 
to working in and around AC drive. Proceed 
with caution.
W662
Human Interface
Module
Hinged Panel
Retaining Lever
External HIM
Cable Connection
Blank Panel Cover
ES
C
SE
L
Stopped
+0.00 Hz