Siemens 300Series 사용자 설명서

다운로드
페이지 170
B-2
ROLMphone 300/600 Series User Guide
Self Test
The Self Test should be the initial step in troubleshooting problems 
with ROLMphone 300/600 series telephones. The purpose of the Self 
Test is to perform an internal check of the telephone. A successful Self 
Test causes all status lights to flicker briefly, and the display, if 
present, to light for one second.
Begin the Self Test
Unplug and replug the line cord from the telephone base and observe 
the status lights and display. (The process of unplugging and 
replugging the line cord from the telephone base is also referred to as 
“resetting the telephone.”)
Note:
Make sure the handset is in its cradle before running the Self 
Test.
Evaluate the Self Test Results
See if the Self Test results match any of the problems listed below. If 
so, follow the recommendations. If not, see if your problem is listed in 
“Other Problems” on page B–2.
All the status lights flash, but the display does not light up.
The telephone has failed the Self Test. Call your system administrator 
or the appropriate service personnel.
No status lights flash when the telephone is reset.
There is a problem with either the telephone base or the line cord. 
Verify that the line cord is connected securely at both ends.
Other Problems
The dial tone is not audible through the handset, though 
everything else works.
Verify that the handset cord is securely connected to both the handset 
and the bottom of the telephone.