Basic operations
Copying the recorded data
This item is used to copy the data to a copy device.
  Copy Data to Copy 1 Drive/Set Copy 1 Drive
This item is used to copy the data to Copy 1 device by speci-
fying the start and end points. The points are specified by 
the date and time or the bookmark. This function is useful for 
copying the data of the short period of time.
 Before executing the copy, make sure that the Copy 1 
device is connected and set in the <Add/Remove HDD 
Device> and <Add/Remove DVD/CD Drive> correctly. 
(System Menu   Memory)
1
1 + 2
3
Copy
2
steps
 1, 2
step
 3
steps
 4, 5
Copy Data to Copy 1 Drive
Set Copy 1 Drive
Range of Copy
User Menu
step
1.  Set the camera number to be copied.
•  The button function changes between “All Off” 
and “All On” each time you select this button. 
You can switch on and off for all the cameras 
easily by using this button.
•  The picture is not copied when there is no 
recorded picture of the set camera number or 
time. Make sure to check that the picture of the  
specified camera has been recorded on the 
specifi ed copy start point.
step
2.  Select “Other settings” and then set the detailed 
settings.
 From 
Device: Sets the device which contains the 
data to be copied. The available setting items are 
“Main” and “Copy 2.”
 From 
Group: Sets the group which contains the 
data to be copied. The available setting items are 
“Normal,” “Alarm,” and “LPA” for main, “SerialBus,” 
“DVD/CD,” and “Internal” for copy 2.
 
To Copy 1: Sets the group to where the data is 
copied. The available setting items are “SerialBus,” 
“DVD/CD,” and “USBmemory.”
 Copy 
Data: Sets the data area to be copied. The 
available setting items are “Alarm” and “All.”
 Overwrite: Selects whether or not to overwrite the 
existed data.
 
Auto Eject: Selects whether to eject media (CD/
DVD) automatically when the copy is over.
 “Alarm” appears for “From Group” when “Alarm Recording 
Area” is set to other than “0 %.” (System Menu   Memory 
 Data Management Setting for Main Memory)
 “LPA” appears for “From Group” when “Long Pre-Alarm 
Area” is set to other than “0 %.” (System Menu   Memory 
 Data Management Setting for Main Memory)
 During copy 2 operation, data cannot be copied from copy 
2 device to copy 1 device. Stop copy 2 operation fi rst and 
then copy the data to copy 1 device.
 When copying the data to DVD while “Overwrite” is set to 
“On,” the unit clears the existing data on the disc before 
overwriting with new data. Note that clearing the data 
takes about 30 to 40 minutes. You cannot cancel opera-
tion during clearing the data of the DVD.
 When copying the data while “Copy Data” is set to “Alarm,” 
the unit performs copy operation, however, the data is not 
copied if there is no alarm recording data within the speci-
fi ed range of copy. In case of CD/DVD disc, the remaining 
capacity becomes low because only the management 
information is recorded. It is recommended to carry out 
“Calculate” in <Copy Data to Copy 1 Drive> to confirm 
whether or not there is alarm recording data in the speci-
fi ed range.
step
3. Select 
<Copy Data to Copy 1 Drive> and select 
“Start,” 
“Start/End,” or 
“End” and then select “Set.” Input the 
start/end time or select the bookmark of copy.
 Start: Sets only the start point of copy. The data 
is copied from the specified start point as much 
data as possible with the remaining capacity of the 
media to be copied.
 Start/End: Sets the start and end points of copy. 
When the amount of data to be copied is larger 
than the capacity of a single CD/DVD disc, copy 
all the desired data to multiple CD/DVD discs 
according to the direction from the recorder.  In 
the case of copying to a USB memory or HDD, 
only the amount of data equal to the available free 
space on the copy destination media is copied.  It 
is recommended to check whether all the desired 
data have been copied properly after the copy is 
fi nished. 
 End: Sets only the end point of copy. The data 
is copied as much data as possible with the 
remaining capacity of the media to be copied until 
the specifi ed end point reaches.
•  To set the bookmark point, select “Bookmark” 
and then select the desired bookmark number.
•  To copy from the oldest recording time, select 
“Copy Start Time.” To copy to the latest 
recording time, select “Copy End Time.”
step
4.  Select “Calculate” to calculate the capacity of data 
to be copied.
 When using “End,” the copy cannot be executed unless 
the calculation of the capacity of data to be copied is com-
pleted.
 When using “Start” or “Start/End” and executing copy 
without calculating the capacity of data to be copied, the 
progress or the time of the copy may not be displayed 
correctly because the unit cannot determine the capacity 
of data to be copied.
 In the case of copying to a USB memory or HDD, when 
the amount of data to be copied is larger than the availa-
ble free space on the copy destination media, the estimat-
ed copy data volume indicates the remaining capacity of 
the copy destination media.  It is recommended to check 
whether all the desired data have been copied properly 
after the copy is fi nished. 
step
5. Select 
“Execute.”
•  The copy starts.
•  To stop copy manually, select “Cancel” in the 
progress screen. The data which has been 
copied before cancelling is copied.