Ethernet Power-On Defaults
The VXIpc-800 Ethernet circuitry loads its power-on settings from an 
EEPROM. You should not change switch S1 from its default setting; 
however, the switch setting required to do so is included in Figure 3-14 
for informational purposes.
Figure 3-14.  Ethernet Power-On Defaults
Installing the VXIpc 800 Series
This section contains general installation instructions for the 
VXIpc-800. Consult your VXIbus mainframe user manual or technical 
reference manual for specific instructions and warnings.
1.
Plug in your mainframe before installing the VXIpc-800. The 
power cord grounds the mainframe and protects it from electrical 
damage while you are installing the module.
Warning: To protect both yourself and the mainframe from electrical hazards, 
the mainframe should remain off until you are finished installing the 
VXIpc-800 module.
2.
Remove or open any doors or covers blocking access to the 
mainframe slots.
3.
If you are installing the VXIpc-800 into a D-size mainframe, install 
a support designed for installing C-size boards in D-size 
mainframes. The VXIpc-800 has no P3 connector and cannot 
provide P3 Slot 0 control to VXI devices requiring this capability.
Caution:
If the VXIpc-800 is not configured for automatic Slot 0 detection, be 
certain that the slot you select in your VXIbus mainframe matches the 
VXIpc-800 configuration as either a Slot 0 device or a Non-Slot 0 device. 
If you install your VXIpc-800 into a slot that does not correspond with the 
jumper setting, you risk damage to the VXIpc-800, the VXIbus backplane, 
or both.
S1
S1
a. Ethernet Power-On Defaults
Loaded from EEPROM
b. Hardwired Ethernet Values
!