16) Cap unused Traveler wire 
17) With button labels right-side up, gently place KeypadLincs into wall boxes and screw in place 
18) Turn power back on 
KeypadLinc’s On button and connected light will turn on 
Only KeypadLinc in box 2 will operate the Load until you synchronize Scenes to the 2 
devices
 
19) Add both KeypadLincs to a Scene as a Controller and Responder of each other (see 
Synchronized Scenes) 
20) Verify both KeypadLincs are working properly by tapping On and Off on a 6 button KeypadLinc or 
MAIN On and Off on an 8 button KeypadLinc turning connected light on and off 
21) Reinstall wallplates 
Installation – Circuit with 3 (or more) Switches 
Circuits with 3 or more switches are called 3-way/4-way circuits. All switches in 3-way/4-way circuits need 
to be replaced by KeypadLincs (and/or SwitchLincs). 
Note: 3-way/4-way circuits require a pair of wires called Travelers between joining wall boxes to operate. 
INSTEON switches, dimmers and keypads do not require both Traveler wires for 3-way/4-way circuits to 
function. Simply wire one to Line, Neutral and Load; the other(s) to Line and Neutral. Use one Traveler to 
share Line between boxes. Adding to a Scene creates a virtual 3-way/4-way circuit. The following 
example shows three switches
 
1)  Turn off circuit breaker(s) and/or remove fuse(s) feeding wall boxes (verify that power is off)  
2)  Pull all three switches from their wall boxes, each existing 3-way switch will have a minimum 3 
wires; 4-way switches will have 4 wires  
3)  Remove wires from existing switches 
4)  Make sure wires are safely separated from each other and turn power back on  
5)  Using a voltage meter measure each wire to Ground in all three boxes until you find the single 
wire supplying 120V (Line) 
a.  We will now refer to that location as box 1  
b.  The location having 2 sets of matching pairs of wires will be box 2 (i.e. 2 Reds and 2 
Blacks, or other matching colors). These are 2 Travelers from box 1 and 2 Travelers 
leading to box 3. 
c.  The last box will have the Load wire, that will be box 3  
6)  Turn power back off  
 
 
In Box 1 (Line box) 
7)  Connect bare Ground wire from 
KeypadLinc to bare Ground wire or 
Ground screw in wall box  
8)  Connect White Neutral wire from 
KeypadLinc to Neutral wire(s) in 
wall box (usually White)  
9)  Cap Red wire from KeypadLinc  
10) Connect Black wire from 
KeypadLinc to 120V Line wire in 
wall box (usually Black) along with 
one Traveler wire running between 
boxes (preferably Black). Note  
color of Traveler you are using as 
this will carry Line voltage to box 2 
11) Cap unused Traveler wire