14.  All horizontal runs of pipe should be as short as possible and are 
required by NFPA No. 211 to have an upward pitch or rise in the same 
direction the smoke travels of no less than 1/4” to the linear foot. 
The connector pipe must meet minimum clearances in any direction 
to walls or other combustible materials. It must attach to a listed 
double wall metal chimney at least 6” in diameter or to a masonry 
chimney with a flue passage of at least 48 square inches.
15.  It is required that a chimney connector pipe not extend further than 
the inner wall of the flue when it is connected to a masonry chimney 
and that it either be cemented to the masonry or be installed without 
cement  in  a  thimble  connected  to  the  masonry  wall.  When  the 
connector is inserted into a thimble, the joint must be tight enough 
so that it will not be dislodged in normal use.
        Install connector at no less than the minimum clearances from the 
ceiling when using a 90-degree elbow to pass through combustible 
constructions.
16.  Chimney connector pipes should never pass through a floor, ceiling, 
fire wall, partition, or combustible construction of any type unless 
certain precautions are taken. The best method is to use a listed 
thimble and a listed chimney in accordance with the manufactures 
directions. NFPA No. 211 gives approved methods for passing a flue 
pipe through combustible constructions.
1.  If  not  previously  installed,  install  floor  protection  and  move  the 
heater into the desired location.
2.  Position the stove on your floor protection in the exact location 
where it is to be located, making sure all minimum clearances are 
met.
3.  If you are installing outside air on your stove, mark a 4” circle on 
the floor protection just below the oblong ring. When cut out, this 
hole will accommodate the flexible outside air tube.
4.  If  the  stove  is  to  be  fastened  to  the  floor,  locate  the  hold  down 
brackets inside the leg box and mark the floor protection below the 
holes in the brackets.
5.  If you are installing outside air on your stove, remove the stove and 
cut the floor protection and the floor where the 4” air tube circle had 
been previously drawn. If the stove is to be fastened to the floor, 
drill 1/2” holes through the floor protection only, at the marks that 
were for fastening the stove to the floor if so desired. Slip the flexible 
outside air tube through the hole in the floor, leaving 1” of tube above 
the floor protector surface, using tape to hold it in place.
6.  Place the stove on the floor protection so that the previously cut or 
drilled holes line up. Attach the stove to the floor with the lag bolts 
if so desired.
7.  If you are installing outside air on your stove place the hose clamp 
over the flexible air tube and slide the tube up over the 4” ring on 
the outside air adaptor box and tighten the hose clamp. Push the 
outside air adaptor forward 1/4” until full contact is made with the 
lower heatshield. Tighten the 1/4” bolt until the adaptor box is held 
firmly in place. Use silicone sealant to create a seal between the 
flexible air tube and your floor protection.
8.  If it is necessary to level, secure or ground your stove, use the holes 
in the bottom of the leg for those applications. To level the stove on 
Olympic cast legs, locate the front leg that is not touching the hearth 
pad. Insert the allen head screw through the slotted washer (supplied 
with the legs) and into the threaded hole in the bottom of the leg. 
See Figure 12. Push the slotted washer down until it touches the 
hearth pad and then tighten the screw into the leg. Should any other 
leg not be resting on the hearth pad, install a washer and screw in 
that leg as well.
9.  Install baffle boards and baffle blanket as per instructions on Pages
14 and 15. It is highly recommended that the baffle be assembled 
before the chimney is installed so that the baffle blanket can be 
adjusted into place through the flue collar.
10.  If installed into a mobile home, the stove shall be grounded to the 
mobile home chassis with a #8 AGW copper wire or equivalent.
11.  For residential installations, install the first section of stove pipe 
with the crimped end going down inside the flue collar on the heater. 
Continue  with  your  stove  pipe,  installing  each  section-crimped 
end down. Make the final connection to your chimney. Your dealer 
carries the necessary pipe and fittings to connect to the various listed 
factory-built chimneys. 
YOUR CHIMNEY INSTALLATION MUST 
COMPLY WITH LOCAL BUILDING AND FIRE CODES.
12.  Be sure to fasten each stove pipe connection with at least 3 sheet 
metal screws.
13.  Install chimney as per manufacturer’s instructions. Some brands of 
pipe may require removal of the spacer ring in the flue collar.
Figure 12
STOVE INSTALLATION
Insert the allen 
head screw 
through the 