240
170PAX4 Maintenance Manual
57518L-001 Rev. A
3/18/05
Preventive and Corrective Maintenance
Printed Circuit Boards—PCMCIA Board
Figure 124 • 10/100 Print Server, Main Logic Board, and Applicator Interface 
Board Electrical Connections
5.
. Carefully remove the three hex screws, spacers, and nuts that secure the 
MLB and the PCMCIA board to the PCB access panel.
6.
Unfasten the PCMCIA board and the main logic board by removing the two hex screws, 
spacers, and nuts.
7.
Disconnect the PCMCIA board from the MLB using the following technique:
a.
Grasp the boards by their edges.
b.
With a gentle rocking and pulling motion, separate the two connectors.
Figure 125 • Screw and Spacer Locations on PCB Access Panel
Note • 
The longer screw and two spacers separate the PCMCIA option board from the 
PCB access panel.
Note • 
The circuit boards may withstand a small amount of flexing; however, they are not 
designed to bend.
Parallel 
Interface 
Connector
Mounting 
Studs
Mounting 
Screw
Serial 
Interface 
Connector
Mounting 
Screw
Main Logic 
Board (MLB)
PCB 
Access 
Panel
PCMCIA Option 
Board
P2 Connector 
on MLB
Applicator 
Interface Board
J3 Power 
Connector
J1 SPI Port 
Connector
Internal 10/100 
Print Server (optional)