Preventive and Corrective Maintenance
Printed Circuit Boards—Cable Harness
57518L-001 Rev. A
3/18/05
170PAX4 Maintenance Manual
267
Figure 145 • Cable Harness Cables, Connectors, and Destinations
for the Left-Hand Model
2.
Feed the 10-position SPI cable (short cable with the red wire) through the main frame 
opening and connect it to the control panel connector.
3.
Align the control panel with the mounting holes in the main frame.
4.
. Reinstall the two control panel mounting screws on the back side of the 
main frame.
5.
. Reconnect a 4-pin connector to P27 on the MLB.
6.
Which printer model do you have?
7.
Reconnect the large 4-pin connector (long cable) to J1 on the AC power supply board.
8.
Slide the PCB access panel completely in to the rear enclosure.
DC Power 
Supply, 
J1
AC Power 
Supply, 
J1
Ribbon Control 
Board,
4-Pin 
Connector, J3
MLB,
4-Pin 
Connector, 
P27
MLB,
8-Position SPI
Control Panel, 
10-Position SPI
DC Power 
Supply, 
J5-J10
DC Power 
Supply, 
J5-J10
DC Power 
Supply, 
J5-J10
If…
Then…
Right-hand model
Reconnect the 6-pin connector to J3 on the applicator interface 
board.
Left-hand model
Reconnect the other 4-pin connector to J3 on the ribbon control 
board.
Important • 
Ensure that all logic board cable leads are tucked in without being pinched 
and the access panel’s metal frame slides into the plastic guide on the bottom of the rear 