Zebra 49834 사용자 설명서

다운로드
페이지 396
Preventive and Corrective Maintenance
Printed Circuit Boards—DC Motor Maintenance
57518L-001 Rev. A
3/18/05
170PAX4 Maintenance Manual
275
DC Motor Maintenance
This procedure is for removing or installing the ribbon take-up or ribbon supply. Read these 
instructions thoroughly before starting.
Tools Required
Installation Instructions
1.
Refer to 
 and remove the print engine from the applicator and open 
the rear enclosure.
Remove the Ribbon Supply/Ribbon Take-Up DC Motor
1.
. Loosen and remove the two 2.5 mm screws that secure the control panel.
2.
. Carefully disconnect the J1 connector from the control panel.
Caution • A qualified service technician must perform this installation.
Caution • Turn OFF (O) the printer and disconnect it from the power source before 
performing the following maintenance.
‰ Phillips Screwdriver Set
‰ Anti-Static Wriststrap and Mat
‰ Standard Hex Key (Allen Wrench) Set
‰ Metric Hex Key (Allen Wrench) Set
Caution • Observe proper electrostatic safety precautions when handling any 
static-sensitive components such as circuit boards and printheads.