Zebra 49834 사용자 설명서
352
170PAX4 Maintenance Manual
57518L-001 Rev. 1
3/18/05
Data Ports
Applicator Interface Connector
11
END PRINT
Output
See
for more
information about the start and end print signals.
• MODE 0—The applicator port is OFF.
• MODE 1—Asserted LOW only while the print
engine is moving the label forward; otherwise
deasserted HIGH.
deasserted HIGH.
• MODE 2—Asserted HIGH only while the print
engine is moving the label forward; otherwise
deasserted LOW.
deasserted LOW.
• MODE 3—Default) Asserted LOW for 20
milliseconds when a label has been completed and
positioned. Not asserted during continuous printing.
positioned. Not asserted during continuous printing.
• MODE 4—Asserted HIGH for 20 milliseconds when
a label has been completed and positioned. Not
asserted during continuous printing.
asserted during continuous printing.
12
MEDIA OUT
Output
Asserted LOW while there is no media in the print
engine.
engine.
13
RIBBON OUT
Output
Asserted LOW while there is no ribbon in the print
engine.
engine.
14
DATA READY
Output
See
for more
information about this signal.
• Asserted LOW when sufficient data has been received
to begin printing the next label.
• Deasserted HIGH whenever printing stops after the
current label, due to either a pause condition or the
absence of a label format.
absence of a label format.
15
SPARE
Output
To be determined.
Table 46 • Applicator Interface Connector Pin Configuration (Continued)
Pin No.
Signal Name
Signal Type
Description
* Applicator boards have separate part numbers for the +5V version (57056M) and the +24-28V version (57389M).