cadsoft eagle 4.5 사용자 설명서

다운로드
페이지 248
Example 5: Layer Setup for an 8-Layer Board
Hints For Working With Blind, Buried, and Micro Vias
VIA command
Depending on the Layer setup vias can have different lengths. The
parameter toolbar of the VIA command shows all available lengths in
the Layer box. When routing manually (ROUTE command) EAGLE
takes the shortest possible via length in order to change layers. It is also
possible that vias at the same position are elongated.
The via length can be changed with the CHANGE VIA command. Se-
lect the value from the according menu and click the via with the left
mouse button.
Alternatively use the command line:
CHANGE VIA 2-7
and a click on the via changes the length from layer 2 to 7.
If the given via length is not defined in the Layer setup it will be elon-
gated to the next possible length or, if this is not possible, an error mes-
sage will be generated.
VIA 'GND' 1-4 (1.05 2)
places a via that belongs to the signal GND and reaches from layer 1 to
4 at position (1.05 2).
ROUTE Command
If you want to change the layer while laying-out the board, EAGLE al-
ways takes the shortest possible via (CHANGE LAYER). It is also pos-
sible that a via at the same position is elongated automatically.
130
EAGLE Manual