ge-interlogix simon 3 사용자 설명서

다운로드
페이지 68
Simon Security System
13
Full Line Seizure
This method requires that the panel be wired ahead (or in front) of all other phones, 
answering machines, computers, or any other devices on the phone line. This allows the 
panel to take over (seize) the phone line, even if another device on the line is in use.
An RJ-31X (CA-38A) jack should be installed when wiring for full line seizure. This 
lets the user quickly and easily disconnect the panel from the phone line in case the 
panel disables the phone line due to a malfunction.
Full Line Seizure Wiring with an RJ-31X
Note  
For UL Listed systems, the 
RJ-31X jack must be 
mounted within 5 feet of the 
panel.
1.
Run a 4-conductor cable from the TELCO block to the RJ-31X (A in Figure 8).
2.
Connect the 4-conductor cable wires to the RJ-31X (B in Figure 8).
3.
Disconnect the Green and Red premises phone jack wires from the TELCO block 
and splice them to the 4-conductor cable Black and White (or Yellow) wires (C in 
Figure 8). Use weatherproof wire connectors for these splices.
4.
Connect the 4-conductor cable Green and Red wires to the TELCO block TIP (+) 
and Red to RING (-) posts (D in Figure 8).
Figure 8. Full Line Seizure Wiring with an RJ-31X
Full Line Seizure Wiring with 1 Premises Phone
Note  
If the customer ever adds a 
phone or other phone device 
to another phone jack, full 
line seizure no longer exists. 
Inform the customer to con-
tact you if they want to add a 
phone or other device so 
that you can rewire for full 
line seizure by adding an 
RJ-31X.
If a single phone is all that exists on the premises, full line seizure can be accomplished 
without an RJ-31X.
1.
Disconnect the phone from the premises phone jack and plug it into the panel 
PHONE jack (A in Figure 9). This jack is disconnected automatically whenever the 
panel reports.
2.
Connect the phone cord included with the panel to the panel LINE IN jack and the 
premises phone jack (B in Figure 9).
H
W
IN
1
H
W
IN
2
E
B
BRN
GRY
GRN
RED
Bla
c
k
Gr
een
Re
d
Wh
it
e
(o
r Y
e
llo
w)
(+)
TIP
(-)
RING
Green
Red
Black
White (or Yellow)
D
A
C
Green
Premises
Phone Jack
Wires
H
W
IN
1
H
W
IN
2
A
B
Lone Premises Phone
Premises
Phone Jack
Figure 9. Full Line Seizure Wiring with 1
Premises Phone